- Sectors
- Food
Cleanrooms for the food industry
Controlled-contamination environments for processing, packaging and storing food products. The HACCP method is built into the design, not the procedures: FSSC 22000, ISO 22000 and EC Regulation 852/2004.
- Cold chain — dedicated HVAC at ±0.5 °C with zone set-points: 0–4 °C on meats, 8–12 °C on MAP packaging
- HEPA H14 filtration — 99.995 % at MPPS to EN 1822, integrated UV-C sanitisation and antibacterial surfaces above the line
- Segregated allergens — independent HVAC circuits, interlocked rapid doors and pressure cascades between allergen and allergen-free zones
- HACCP traceability — seven critical points under control, BMS with continuous logging and early alarm under 2 seconds
- ISO 5–8Classes delivered for the sector
- HACCPMethod built into the design
- ±0.5 °CThermal stability in the room
- AuditAudit-ready documents, where required
Food groups, processing industries, research centres
They entrusted Phamm Engineering with their controlled-contamination environments, from design to qualification.
Three classes, three different risks
The class is not decided by the finished product: it is decided by how long the product stays exposed and who it is intended for. The limits are those of ISO 14644-1 for 0.5 µm particles.
- ISO 5≤ 3,520 part./m³
Ultra-sensitive processing
Ready-to-eat preparations, food for infants and the immunocompromised, raw-milk products: where the airborne microbial load goes straight into the shelf life.
Ready-to-eat · Infant food - ISO 7≤ 352,000 part./m³
MAP packaging and cutting
Modified-atmosphere packaging, meat cutting and portioning lines, ready-prepared salads and fresh-cut products.
MAP · Ready-prepared salads · Fresh-cut - ISO 8≤ 3,520,000 part./m³
Storage and preparation
Storage of sensitive raw materials, ingredient preparation and mixing, microbiological quality control laboratory.
Storage · Mixing · QC
Six problems that food brings and other sectors do not
Every item is a requirement with a number and a standard behind it. If a requirement has no measure, it is not a requirement.
Uninterrupted cold chain
Direct-expansion or chilled-water air handling units, control accuracy ±0.5 °C, distributed PT100 probes and thermal barriers between adjacent rooms. Differentiated set-points by zone, because cutting and packaging do not want the same temperature.
Microbial load below the limits
HEPA H14 filtration at 99.995 % at MPPS, combined with integrated UV-C sanitisation and antibacterial surfaces. The airborne load falls below the HACCP limits set for the product’s risk class, measured and not estimated.
Physically separated allergens
Real segregation, not procedural: fully independent HVAC circuits between allergen and allergen-free zones, interlocked rapid doors, differential pressures that prevent airborne transfer and qualified sanitisation protocols.
No going back
Unidirectional-flow layout — forward flow — with flushed trolley pass-throughs between zones and pressure cascades that make cross-contamination between areas of different hygiene classification impossible.
Total washability
Monolithic resin with slope and drain channel, coved joints between floor and wall, non-porous materials certified for food contact, resistant to aggressive detergents and CIP foam cycles.
Seven critical points under control
Every CCP is covered by the infrastructure, not by a procedure: environmental sensors, automatic BMS logging of temperature, humidity, differential pressures and particle count, early alarm under 2 seconds.
The cold is a chain: it breaks at its weakest link
Between the receipt of raw materials and the storage of the finished product, the product passes through six rooms, and each has its own operating temperature. They do not all need to be cold: what matters is that none leaves its own range, ever, for the whole shift.
That is why the cleanroom is born with the thermal map already written: set-point and tolerance per zone, thermal barriers where two ranges meet, probes where the gradient is worst and not where it is convenient to mount them. The data is logged continuously, so a drift is seen as it begins and not at the end of the batch.
- ±0.5 °CControl accuracy
- 6 zonesUnder continuous control
- 100 %Data logging
Six steps, one point of contact
It is the same path across all ten sectors: what changes is what we look at at each step, not who answers.
-
01
Analyse
Process, standards and site constraints: from these come the class and the URS that sets it.
-
02
Design
Layout, separate flows, pressure cascade and HVAC, verified on BIM and CFD models.
-
03
Manufacture
Panels, metalwork and switchboards in our workshop, with factory acceptance testing (FAT).
-
04
Install
On-site assembly, systems and monitoring, on-site verification (SAT) and start-up.
-
05
Qualify
We carry out the tests and deliver audit-ready documentation, where required.
-
06
Support
Scheduled maintenance, filters and calibration, even on systems by others.
Where our cleanrooms end up
Six areas with requirements that differ from one another: the temperature changes, the humidity changes, the way of washing changes.
Meat processing
Cutting, boning, portioning and packaging of fresh meat with the room at 0–4 °C and filtration over the line.
ISO 7 · 0–4 °CMAP packaging
Modified atmosphere on fresh products, ready-prepared salads and ready meals: extended shelf life without additional additives.
ISO 7 · MAPDairy
Fresh cheeses, yogurt and milk derivatives in a controlled relative-humidity environment, with prevention of cross-contamination.
ISO 7–8Bakery and confectionery
Packaging of bakery products, chocolate and confectionery at controlled temperature and humidity, so as not to alter structure and aroma.
ISO 8Baby food and special foods
Foods for infants, supplements and products for special dietary regimes, with the highest hygiene requirements in the sector.
ISO 5–7Microbiological QC laboratory
Sample analysis, colony counting, shelf-life tests and process validation in a controlled-contamination environment.
ISO 7
The regulatory framework we apply
Environmental classification, food safety, surface hygiene and biocontamination control. Thirteen documents, all applicable in the same cleanroom.
- ISO 14644-1:2015
- ISO 14644-3:2019
- HACCP / Codex Alimentarius
- ISO 22000:2018
- FSSC 22000
- BRC Global Standard Food Safety
- IFS Food
- Reg. EC 852/2004
- Reg. EC 853/2004
- Reg. EC 178/2002
- EN 1672-2
- EN 17141
- GHP — Good Hygiene Practices
Cleanrooms for the food industry
The questions we receive most often from production and quality managers, with the short answer.
Which ISO class is needed for meat processing?
For cutting, boning and portioning, ISO 7 is the standard: it guarantees a maximum of 352,000 particles of 0.5 µm per cubic metre, enough to reduce airborne contamination in the phases where the product is exposed. On meat-based ready-to-eat products we recommend ISO 5 on the final packaging zone only: it is the last point where the environment can still enter the product.
How is the cold chain maintained inside a cleanroom?
With direct-expansion or chilled-water air handling units capable of ±0.5 °C, PT100 probes distributed at critical points and a BMS that adjusts air flow and cooling power in real time. Zones have differentiated set-points — 0–4 °C on meats, 8–12 °C on MAP packaging — with thermal barriers between adjacent rooms, because two different temperatures in contact without a barrier cancel each other out.
How are allergens managed?
With physical, not procedural, segregation: fully independent HVAC circuits between allergen and allergen-free zones, interlocked quick-closing doors, differential pressures that prevent airborne transfer of allergenic particles and qualified sanitisation protocols for trace removal. Surfaces are non-porous, floor-to-wall joints are coved and drains are dedicated per zone.
Is the cleanroom compliant with HACCP requirements?
It is by construction, not by later certification. The forward-flow layout prevents cross-contamination, pressure cascades protect the higher-risk zones, cladding materials are certified for food contact and withstand chemical sanitisation. The BMS automatically logs temperature, humidity, differential pressures and particle count: the documentation for FSSC 22000, BRC and IFS audits comes out of the system, not out of a notebook.
What is the difference between a food cleanroom and a pharmaceutical one?
They share the ISO 14644 basis for classification and diverge on everything else. Food follows HACCP, FSSC 22000 and EC Regulation 852/2004, with the focus on microbiological contamination and the cold chain. Pharmaceutical follows GMP Annex 1 with grades A-B-C-D and stricter requirements on particles and environmental monitoring. We design both, with teams that know the difference.
What does the cost of a food cleanroom depend on?
On the class and number of zones, the operating temperature, air changes per hour, the type of flooring and drains, the level of automation and the extent of allergen segregation — which is the item most often underestimated. Describe the process and the site constraints to us: we reply with a detailed quote.
Describe the process, not just the square metres
Class by zone, operating temperatures, presence of allergens, line rate, type of washing. With these elements the quote is accurate first time, built on your process.
- IT+39 02 8364 7535
- ES+34 673 889 559
- info@phammeng.com
- Pozzo d’Adda (MI), Italy