- Sectors
- Automotive
Cleanrooms for the automotive industry
Controlled-contamination environments for premium painting, autonomous-driving sensors, battery cells and on-board electronics. Designed to OEM and Tier 1 specifications, with documentation compliant with IATF 16949 and VDA 6.3.
- Class A finish — laminar downflow at 0.3 m/s, multistage filtration with pre-filter and HEPA H13/H14, overspray protection
- EV battery cells — dry room with dew point below −40 °C, i.e. less than 1 % relative humidity, in ISO 5–6
- ESD protection — dissipative floors, air ionisers and earthing of every workstation, compliant with IEC 61340-5-1
- Line rate — layout for just-in-time and just-in-sequence flows, AGV-compatible access, integration with the plant MES
- ISO 5–8Classes delivered for the sector
- IATF 16949Reference quality system
- 0.3 m/sAirflow velocity in the booth
- AuditAudit-ready documents, where required
Manufacturers, Tier 1, industrial groups and research centres
They entrusted Phamm Engineering with their controlled-contamination environments, from design to qualification.
Three classes, three ways to ruin a part
In the same factory a particle causes a cosmetic defect, shifts a measurement or triggers a short circuit. The class is written on the risk, not on the department. The limits are those of ISO 14644-1 for 0.5 µm particles.
- ISO 5≤ 3,520 part./m³
ADAS sensors and battery cells
Assembly and calibration of LiDAR, radar and cameras for autonomous driving, production of lithium cells. A particle on the optics degrades the signal; one in the cell makes it a hazard.
ADAS · EV cells - ISO 6≤ 35,200 part./m³
Premium painting
OEM paint booths, clearcoat application, metallic finishes: the surfaces the customer looks at up close, where an inclusion is visible to the naked eye.
Paint shop · Class A - ISO 7–8≤ 352,000 part./m³
Assembly and testing
ECU control units, battery management systems, inverters, infotainment modules, LED and laser lighting, functional test benches in an ESD-protected environment.
ECU · Infotainment · Testing
Six problems that automotive brings and other sectors do not
Every item is a requirement with a number and a standard behind it. If a requirement has no measure, it is not a requirement.
Paint defects
An inclusion, a crater or orange peel means rework or scrap. Laminar downflow at 0.3 m/s carries particulate away from the surface instead of stirring it back: in ISO 6 the concentration drops by a hundred to a thousand times compared with a conventional booth.
Sensor contamination
On a LiDAR or an autonomous-driving camera, contamination does not cause a cosmetic defect: it shifts the measurement. Assembly and calibration in ISO 5 ESD-safe, with particulate control on the optics at every step.
Lithium cell safety
Even a microscopic metal particle can pierce the separator between anode and cathode: internal short circuit and risk of thermal runaway. You need a dry room in ISO 5–6 with dew point below −40 °C, not just a clean room.
Electrostatic discharge
Conductive or dissipative floors, earthed work surfaces, bipolar air ionisers over non-conductive surfaces and common workstation earthing. Periodic verification of resistivity, ionisers and surface potential.
Integration without line stoppage
The rooms are modular and fit between existing line sections: access compatible with AGVs, conveyor belts and robotic arms, installation planned within already scheduled stoppages. Production does not stop to make room for the cleanroom.
Traceability and audits
Every part carries its own identity and every batch its own environmental conditions: qualification documentation, PPAP with special processes, correlation between environmental data and line scrap, reporting compliant with IATF 16949 and VDA 6.3.
Particulate and scrap are the same curve
Particle count and line defect rate have different units and the same shape. When you put them on the same time axis the overlap is visible at a glance, and from then on the environment stops being a requirement to certify and becomes a process lever.
That is why the room’s environmental monitoring is linked to the line’s scrap and rework data: a drift in particulate reads as an early warning of defects, days before it reaches acceptance testing. Reporting is compliant with IATF 16949, already in the form auditors ask for.
- AuditAudit-ready documents, where required
- PPAPDocumented special processes
- VDA 6.3Process audits supported
Six steps, one point of contact
It is the same path across all ten sectors: what changes is what we look at at each step, not who answers.
-
01
Analyse
Process, standards and site constraints: from these come the class and the URS that sets it.
-
02
Design
Layout, separate flows, pressure cascade and HVAC, verified on BIM and CFD models.
-
03
Manufacture
Panels, metalwork and switchboards in our workshop, with factory acceptance testing (FAT).
-
04
Install
On-site assembly, systems and monitoring, on-site verification (SAT) and start-up.
-
05
Qualify
We carry out the tests and deliver audit-ready documentation, where required.
-
06
Support
Scheduled maintenance, filters and calibration, even on systems by others.
Where our cleanrooms end up
Six areas with requirements that differ from one another: the class changes, the humidity changes, the way of protecting the part changes.
Premium OEM painting
Downflow booths for bodies, bumpers and exterior components, with a Class A finish on surfaces seen up close.
ISO 6 · Class AADAS and LiDAR sensors
Assembly and calibration of autonomous-driving sensors, surround-view cameras and radar in an ESD-safe environment.
ISO 5 · ESDBattery cells and modules
Production of lithium cells in a dry room with relative humidity below 1 %; assembly of modules and packs in at least an ISO 7 environment.
ISO 5–6 · dry roomControl units and powertrain
SMT assembly of engine control units, battery management systems and traction inverters in an ESD-protected environment.
ISO 7 · ESDLED and laser lighting
Production of matrix headlights and laser headlights: optics free of inclusions and condensation, where an internal defect cannot be recovered.
ISO 6–7Displays and infotainment
Assembly and bonding of head-up displays, touchscreens and instrument clusters, in a low particle-contamination environment.
ISO 6–7
The regulatory framework we apply
Environmental classification, automotive quality system, technical cleanliness of components and electrostatic management. Nine documents, all applicable in the same cleanroom.
- ISO 14644-1:2015
- ISO 14644-3:2019
- IATF 16949
- VDA 6.3
- VDA 19
- ISO 16232 — technical cleanliness
- IEC 61340-5-1 — ESD
- ANSI/ESD S20.20
- ISO 9001:2015
Cleanrooms for the automotive industry
The questions we receive most often from those who design the line and those who answer for quality, with the short answer.
Why is a cleanroom needed for painting?
Because a Class A finish allows no visible defects, and every inclusion, crater or orange peel is paid for in rework or scrap. An ISO 6 booth with laminar downflow lowers the particle concentration by a hundred to a thousand times compared with a conventional booth: the particulate is carried away from the surface while the paint is still wet, which is the only moment that matters.
Which class is needed to produce battery cells?
For lithium cells we work in ISO 5–6 with extreme humidity control: a dry room with dew point below −40 °C, which corresponds to less than 1 % relative humidity. Metal particles, even microscopic ones, can pierce the separator between anode and cathode and cause an internal short circuit with risk of thermal runaway. For the assembly of battery modules and packs at least ISO 7 is needed.
Can a cleanroom be integrated into a line already in production?
Yes, and it is the most frequent case. The rooms are modular and are designed around the existing layout: AGV-compatible access, conveyor belts and robotic arms, utility connections prepared in advance and installation planned within already scheduled stoppages. The schedule is built on the production calendar, not the other way round.
Do you support IATF 16949 and VDA 6.3 audits?
Yes. We provide the qualification documentation the sector requires, ISO 14644 certifications, PPAP with documentation of special processes, traceability of the materials used and on-site technical support during audits by the main European OEMs and certification bodies.
What maintenance is needed, and how much does it stop the line?
Scheduled maintenance contracts with downtime SLAs: filter replacement, ISO 14644 recertification, ESD checks on floor resistivity, ionisers and surface potential, calibration of environmental sensors and HVAC maintenance. Interventions are planned around your production schedules, because in automotive downtime costs more than the spare part.
What does the cost depend on?
On the class and number of stations, the presence or absence of a dry room, the extent of the ESD network, the HVAC capacity needed to offset the machines’ thermal load and the complexity of integration with the existing line. An ISO 7 for ECU assembly and an ISO 6 paint booth are two different works. Describe the line to us: we reply with a detailed quote.
Describe the line, not just the square metres
Class per station, line rate, ESD requirements, presence of a dry room, downtime constraints and customer specifications. With these elements the quote is accurate first time, built on your process.
- IT+39 02 8364 7535
- ES+34 673 889 559
- info@phammeng.com
- Pozzo d’Adda (MI), Italy