Equipment and components for cleanrooms

The room and the envelope; this equipment is what works inside them. Filtration, containment, material transit and personnel entry: designed together with the cleanroom and built in the same plant.

  • From the ceiling filter module to the steel furniture on the floor.
  • Built by us with the drawing on file, and therefore with the spare part still available tomorrow.
  • Made to measure for the room dimensions, material and finish follow the specification, not the catalogue.
  • Also on other people’s systems the equipment fits where someone else built the cleanroom.
The fitted wall The families
Elevation of a wall: air shower, interlocked pass-through, trolley pass-through, isolator. The openings in the wall are the real product.
  • 8families
  • AISI 316reference steel
  • H13–U15filter classes
  • ISO 5–8classes served
They chose us

Pharmaceutical, medical, electronics, food and those who work for them

The same families change specification from one sector to another: the material, the finish and the test they must pass change.

  • L’Oréal Paris
  • Fratelli Beretta
  • Bill & Melinda Gates Foundation
  • PharmaJet
  • University of Pisa
  • Fiat Aviazione
  • Solvay
  • Epson
  • Actavis
  • Kolektor
  • PAN Compositi
  • Ansaldo Energia
  • University of Milan
  • Spes Medica
Challenges and solutions

Where equipment choices go wrong

Six mistakes that are paid for later, when the room is already in operation and changing a component means stopping the process.

  • The catalogue component inside a made-to-measure specification

    A piece chosen from the price list does not know the class of the room, the required finish or the detergents that will pass over it. Dimensions are taken from the room, not from the catalogue: it is the reason we design the critical pieces ourselves.

  • The passage that opens a path for air

    A pass-through without an interlock will sooner or later find itself with both doors open at once: at that instant the pressure cascade no longer exists. The interlock is mechanical or electrical, but it is not an accessory.

  • Equipment that cannot be cleaned

    Sharp edges, visible screws, non-continuous joints: these are the points where cleaning stops and residue remains. Radiused corners, continuous welds and smooth surfaces are not aesthetics, they are the condition for the cleaning procedure to work.

  • The spare part that no longer exists after eight years

    The commercial component goes out of production and the supplier proposes the new model, which has different dimensions. If the drawing is on file the part is remade identical, and the room does not have to be requalified for a spare part.

  • The hood chosen by name instead of by standard

    A laminar flow protects the product and blows towards the operator; a biological safety cabinet according to EN 12469 also protects the operator and the environment. They are two different machines: choosing them out of habit exposes someone.

  • The isolator without a transfer system

    The barrier is only as good as the way materials enter and leave. Rapid port, ventilated pass-through or double-door connection: it is decided with the process in hand, because after installation it can no longer be changed.

In-house production

From sheet metal to testing, without leaving the plant

Cutting, bending, welding, finishing and testing all take place in Pozzo d’Adda. It is not a matter of industrial pride: it is the reason a non-standard dimension does not become a surcharge and a wait.

And above all it is the reason the spare part still exists in eight years. The drawing stays on file: the part is remade identical, with the same material and the same tolerances as the one it replaces.

Plant Pozzo d’Adda
  • Sheet metalCut and bent in-house
  • WeldingContinuous, then finished
  • TestingBefore shipment
How we work

Six steps, one point of contact

The equipment comes in at the third step and not the last: dimensions and constraints are decided with the room, not after closing it.

  1. 01

    Analyse

    Process, standards and site constraints: from these come the class and the URS that fixes it.

  2. 02

    Design

    Layout, separate flows, pressure cascade and HVAC, verified on BIM and CFD models.

  3. 03

    Manufacture

    Panels, metalwork and control panels in our workshop, with factory acceptance testing (FAT).

  4. 04

    Install

    On-site assembly, systems and monitoring, on-site verification (SAT) and start-up.

  5. 05

    Qualify

    We carry out the tests and deliver audit-ready documentation, where required.

  6. 06

    Support

    Scheduled maintenance, filters and calibration, including on systems built by others.

Reference standards

The standards that concern the equipment

Cited with part and edition: without them, a declaration of conformity cannot be verified.

  • ISO 14644-1:2015
  • ISO 14644-3:2019
  • ISO 14644-7:2004
  • ISO 10648-2:1994
  • EN 1822-1:2019
  • EN 12469:2000
  • EU GMP Annex 1:2023
  • EN 17141:2020
  • ISO 9001:2015
  • AISI 304 · AISI 316
Frequently asked questions

Questions that come back with every equipment choice

The questions that come back on every site survey, with the answer we would give in person.

Can I install your equipment in a cleanroom built by others?

Yes. A survey is needed: opening dimensions, panel thickness and type, room class and direction of pressures. From there the piece is designed on the opening that exists, not on the opening we would have made ourselves.

What is the difference between a laminar flow hood and a biological safety cabinet?

The first protects the product: filtered air descends onto the surface and exits towards the operator. The second, according to EN 12469, protects product, operator and environment because the outgoing air is also filtered. If biological or cytotoxic material is handled, the first is not enough.

Positive or negative isolator: how to choose?

You choose by looking at who must be protected. Under overpressure the air flows out of the barrier and protects the product from what is outside; under underpressure the air flows in and protects the operator and the environment from what is inside. The leak-tightness classification is assessed according to ISO 10648-2.

Static or ventilated pass-through?

Static when it only needs to separate two zones and the material does not release particulate. Ventilated — with its own filter unit — when the load must be decontaminated during the dwell or when the differential between the two zones is important.

AISI 304 or AISI 316?

304 is fine in most rooms. 316, which contains molybdenum, resists chlorides and aggressive detergents better: it is used where the cleaning plan is severe or where there are saline solutions. The choice is written in the specification, not left to the supplier.

Ceiling filter units: HEPA or ULPA?

It depends on the class to be maintained and on the contaminant. Filter classes are cited according to EN 1822 — from H13 up for HEPA, from U15 for ULPA — and are chosen on the requirement, not by maximising them out of habit: a finer filter costs in pressure drop and in consumption for the whole life of the plant.

Let’s talk

Tell us what the room has to do

With the opening dimensions and the class to be maintained, we arrive at a proposal that stands up. The site survey is the quickest way not to get the dimensions wrong.